| V3
- The most exciting innovation in gas fired unit heaters for
many years. Reznors extensive research and development
has resulted in a technically advanced range of unit heaters
that deliver the highest possible standards of energy efficiency
and performance. |
| Incorporating
a radical new heat exchanger and burner V3 is compact, lightweight
and provides end users, consulting engineers and installation
contractors with the ultimate unit heater solution. |
|
|
| |
| Energy
Saving |
 |
4-pass
heat exchanger achieves over 92% thermal efficiency. |
 |
Reduced
carbon dioxide and NOx emissions. |
 |
Eligible
for 100% enhanced capital allowances. |
 |
Improved
airflow and new louvre design give longer air throws and
significantly reduces stratification within the building. |
|
 |
 |
Aerodynamic
heat exchanger profile enables up to 20% increase in airflow
with a 30% reduction in electrical consumption. |
| |
|
|
|
|
| Easy
Installation and Maintenance |
 |
Up
to 37% lighter than comparative models. |
 |
Balanced
flue wall terminal provides both flue outlet and combustion
air inlet thereby reducing installation time. |
 |
Balanced
flue units eliminate the need for combustion air grilles
in the wall. |
|
|
|
| Application
Versatility |
 |
Both
horizontal and vertical down flow
(combined heating/ destratification) units are available. |
 |
The
smallest unit is only 310mm high - Making it ideal for
mounting in confined areas e.g. underneath mezzanine floors. |
|
|
|
|
| |
|
|
| V3
is suitable for a wide range of applications - industrial
and commercial premises; retail; sports and leisure; warehouses,
logistics and distribution centres. |
| Vertical
downflow models are ideal for warehouse heating. |
 |
|
|
|
| |
| Enhanced
Safety |
 |
Room
sealed units draw combustion air from outside the building thereby
preventing contaminants from entering the combustion zone. |
|
|
| |
| Extended
Operational Life |
 |
The
titanium stabilised aluminised steel heat exchanger is particularly
strong and durable providing additional temperature resistance.
Its weld free construction ensures long life. |
|
|
| |
 |
| |
| MODEL
|
|
|
UDSA
008 |
UDSA
011 |
UDSA
015 |
UDSA
020 |
UDSA
025 |
UDSA
030 |
UDSA
035 |
UDSA
043 |
UDSA
050 |
UDSA
055 |
UDSA
064 |
UDSA
073 |
UDSA
0085 |
UDSA
100 |
| Nominal
heat output |
|
kW
|
7
|
11
|
15
|
18
|
26
|
29
|
35
|
42
|
49
|
55
|
64
|
73
|
85
|
97
|
| Airflow
|
|
m³/h |
680
|
1020
|
1360
|
1700
|
2385
|
2725
|
3510
|
4535
|
5180
|
5830
|
6810
|
7770
|
9065
|
10360
|
| Temperature
rise |
|
0C
|
32
|
32
|
32
|
32
|
32
|
32
|
31
|
28
|
28
|
28
|
28
|
28
|
28
|
30
|
| Throw
(1) |
|
m
|
8
|
10
|
13
|
16
|
20
|
22
|
25
|
28
|
30
|
30
|
33
|
35
|
36
|
39
|
| Noise
Level (free field @ 5 metres) |
|
dB(A)
|
40
|
39
|
40
|
41
|
43
|
44
|
48
|
50
|
51
|
52
|
53
|
53
|
53
|
54
|
| Noise
Level (typical installation @ 5 metres) |
|
dB(A)
|
47
|
46
|
47
|
48
|
50
|
51
|
55
|
57
|
58
|
59
|
60
|
60
|
60
|
61
|
| Gas
consumption(2) |
Nat
Gas G20 |
m³/h |
0.84
|
1.26
|
1.68
|
2.1
|
2.94
|
3.36
|
4.03
|
4.85
|
5.59
|
6.3
|
7.41
|
8.4
|
9.8
|
11.19
|
|
Propane
G31 |
kg/h
|
0.63
|
0.94
|
1.26
|
1.57
|
2.2
|
2.51
|
3
|
3.66
|
4.18
|
4.71
|
5.5
|
6.27
|
7.32
|
8.37
|
| Gas
connection(3) |
|
Rc |
1/2
|
1/2
|
1/2
|
1/2
|
1/2
|
1/2
|
3/4
|
3/4
|
3/4
|
3/4
|
3/4
|
3/4
|
3/4
|
3/4
|
| Mounting
Height(4) |
|
m
|
2.0-2.5
|
2.0-2.5
|
2.0-3.0
|
2.0-3.0
|
2.0-3.5
|
2.0-3.5
|
2.5-3.5
|
2.5-3.5
|
2.5-3.5
|
2.5-3.5
|
3.0-4.0
|
3.0-4.0
|
3.0-4.0
|
3.0-4.0
|
| Total
electrical rating |
(230V/50Hz)
|
kW
|
0.12
|
0.12
|
0.13
|
0.13
|
0.27
|
0.27
|
0.35
|
0.37
|
0.43
|
0.49
|
0.68
|
0.85
|
0.85
|
0.85
|
| Net
weight |
|
kg
|
30
|
33
|
38
|
40
|
56
|
60
|
88
|
99
|
99
|
112
|
118
|
143
|
158
|
168
|
|
| |
| |
Note:
1. Isothermic condition (20°C). Throw is dependent on mounting
height, building height, room
temperature and louvre settings. |
| |
2.
Natural gas G20 Calorific value 10.5 kWh m3GCV, inlet gas pressure
maximum 50mbar, minimum 17.5mbar.
Propane G31 Calorific value 14.0 kWh/kg GCV, inlet gas pressure maximum
50mbar, minimum 37mbar. |
| |
3.
Not supply line size. |
| |
4.
Recommended height to underside of heater for standard horizontal
discharge units. Downturn nozzles are recommended for units installed
at the higher mounting height. Please consult Reznor. |
|
| |
|
| |
 |
| |
| MODEL
|
UDSA
008 |
UDSA
011 |
UDSA
015 |
UDSA
020 |
UDSA
025 |
UDSA
030 |
UDSA
035 |
UDSA
043 |
UDSA
050 |
UDSA
055 |
UDSA
064 |
UDSA
073 |
UDSA
085 |
UDSA
100 |
| A
|
310
|
310
|
385
|
385
|
590
|
590
|
510
|
510
|
510
|
665
|
665
|
865
|
865
|
865
|
| B
|
675
|
675
|
675
|
675
|
675
|
675
|
970
|
970
|
970
|
970
|
970
|
1040
|
1040
|
1040
|
| C
(1) |
415
|
415
|
415
|
415
|
415
|
415
|
625
|
625
|
625
|
625
|
625
|
675
|
675
|
675
|
| D |
660 |
660 |
685 |
700 |
725 |
745 |
1070 |
1070 |
1070 |
1140 |
1140 |
1150 |
1150 |
1150 |
| E(1) |
350 |
350 |
350 |
350 |
350 |
350 |
600 |
600 |
600 |
600 |
600 |
600 |
600 |
600 |
| F |
100 |
100 |
100 |
100 |
100 |
100 |
150 |
150 |
150 |
150 |
150 |
150 |
150 |
150 |
| G(1) |
|
|
413 |
|
413 |
|
622 |
622 |
622 |
622 |
622 |
672 |
672 |
672 |
| H(1) |
|
|
250 |
|
450 |
|
400 |
400 |
400 |
500 |
500 |
500 |
500 |
500 |
| Flue
outlet dia J |
80 |
80 |
80 |
80 |
100 |
100 |
100 |
100 |
100 |
130 |
130 |
130 |
130 |
130 |
| Air
inlet dia K |
80 |
80 |
80 |
80 |
100 |
100 |
100 |
100 |
100 |
130 |
130 |
130 |
130 |
130 |
| Top
clearance |
50 |
50 |
50 |
50 |
50 |
50 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
| Rear
clearance |
450 |
450 |
450 |
450 |
450 |
450 |
450 |
450 |
450 |
450 |
450 |
450 |
450 |
450 |
| Bottom
clearance |
50 |
50 |
50 |
50 |
50 |
50 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
| Side
clearance |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
| Access
clearance |
850 |
850 |
850 |
850 |
850 |
850 |
850 |
850 |
850 |
850 |
850 |
850 |
850 |
850 |
|
|
| |
| |
Note:
1.
= Suspension centres.
*Clearance required for combustibles - units may be base mounted on
suitable non-combustible supports.
All dimensions in mm. |
| |
Only
highlighted products are available as downflow units - ( UDSA 015,
025, 035, 043, 050, 055, 064, 073
085, 100 ) |
|
| |
|
| |
|