hvac, space heaters, heaters, industrial, space heating, heating systems

heat, hvac, space heaters, propane heaters, heating, swimming pool heaters, reznor
l l l l l l
 
 
 
 
 
 
Designed for use in a wide range of free blowing commercial and industrial applications such as workshops, garages, production facilities and warehouses, UCA heaters offer a cost effective efficient means of space heating. Units may be either suspended or mounted on wall brackets so that they do not infringe on valuable floor space.
 
Benefits
Easy installation and maintenance
Low cost
 
Features
Conventional flue
Axial fan
Suitable for natural gas (G20)
Aluminised steel heat exchanger
Horizontal louvres
Piezo ignition system
   
Options
Vertical louvres
Downturn nozzles (30° and 60°)
Suitable for propane gas
Economy thermostat
Wall mounting brackets
   
 
 
MODEL unit UCA 25 UCA 30 UCA 35 UCA 45 UCA 55 UCA 75 UCA 95
Nominal Heat output kW 24 28 34 41 51 70 93
Air flow (@ 15°C) m³/h 1700 2400 3700 3700 4200 5600 7900
Temperature rise K 41 33 27 32 35 36 34
Throw (1) m 17 20 28 28 28 32 38
Gas Consumption nat.gas G20 (2) m³/h 2.89 3.33 4.13 4.97 6.17 8.49 11.33
propane G31 (3) kg/h 2.16 2.49 3.09 3.72 4.62 6.35 8.48
Gas connection (4) Rc 3/4 3/4 3/4 3/4 3/4 3/4 3/4
Fan motor(s) rating kW 0.075 0.12 0.12 0.12 0.12 2x0.12 2x0.12
Total electrical rating kW 0.11 0.15 0.23 0.23 0.23 0.31 0.51
Sound pressure level (Lp)@5m free field dB(A) 44 44 47 47 47 48 51
typical
installation
dB(A) 51 51 54 54 54 55 58
Suggested mounting
height (5)
m 2.0-2.5 2.0-2.5 2.5-3.0 2.5-3.0 2.5-3.0 2.5-3.5 2.5-3.5
Approximate weight kg 72 84 100 100 116 145 183
 
  1. Throw depends on height of building, mounting height of heater, room temperature and louvre settings
  2. Natural Gas – minimum inlet pressure 17.5 mbar, maximum inlet pressure 50mbar
  3. Propane Gas – minimum inlet pressure 37 mbar, maximum inlet pressure 50mbar
  4. Not supply line size
  5.To underside of heater
   
 
   
 
 
MODEL unit UCA 25 UCA 30 UCA 35 UCA 45 UCA 55 UCA 75 UCA 95
Cabinet width A 520 590 730 730 870 1080 1360
Access side to flue centre B 290 325 395 395 465 570 710
Side clearance non control side C 150 150 150 150 150 300 300
Access side clearance D 550 620 750 750 900 1100 1400
Cabinet back to flue outlet E 127 137 151 151 162 162 169
Flue outlet diameter (inches) F 5 6 7 7 8 8 10
Depth axial fan G 218 249 278 278 318 249 318
Suspension centres H 359 429 569 569 709 919 1199
 
  All dimensions in mm except flue outlet diameter which is in inches.
   
   

Tel.. 01303 259141

Fax.. 01303 850002

sales@reznor.co.uk

An Ambi-Rad Group Company