| Designed
for use in a wide range of free blowing commercial and industrial
applications such as workshops, garages, production facilities
and warehouses, UCA heaters offer a cost effective efficient
means of space heating. Units may be either suspended or mounted
on wall brackets so that they do not infringe on valuable floor
space. |
| |
| Benefits |
 |
Easy
installation and maintenance |
 |
Low
cost |
|
|
|
|
| |
| Features |
 |
Conventional
flue |
 |
Axial
fan |
 |
Suitable
for natural gas (G20) |
 |
Aluminised
steel heat exchanger |
 |
Horizontal
louvres |
 |
Piezo
ignition system |
| |
|
|
|
| Options |
 |
Vertical
louvres |
 |
Downturn
nozzles (30° and 60°) |
 |
Suitable
for propane gas |
 |
Economy
thermostat |
 |
Wall
mounting brackets |
| |
|
|
|
|
| |
 |
| |
| MODEL |
unit |
UCA
25 |
UCA
30 |
UCA
35 |
UCA
45 |
UCA
55 |
UCA
75 |
UCA
95 |
| Nominal
Heat output |
kW |
24 |
28 |
34 |
41 |
51 |
70 |
93 |
| Air
flow (@ 15°C) |
m³/h |
1700 |
2400 |
3700 |
3700 |
4200 |
5600 |
7900 |
| Temperature
rise |
K |
41 |
33 |
27 |
32 |
35 |
36 |
34 |
| Throw
(1) |
m |
17 |
20 |
28 |
28 |
28 |
32 |
38 |
| Gas
Consumption |
nat.gas
G20 (2) |
m³/h |
2.89 |
3.33 |
4.13 |
4.97 |
6.17 |
8.49 |
11.33 |
| propane
G31 (3) |
kg/h |
2.16 |
2.49 |
3.09 |
3.72 |
4.62 |
6.35 |
8.48 |
| Gas
connection (4) |
Rc |
3/4 |
3/4 |
3/4 |
3/4 |
3/4 |
3/4 |
3/4 |
| Fan
motor(s) rating |
kW |
0.075 |
0.12 |
0.12 |
0.12 |
0.12 |
2x0.12 |
2x0.12 |
| Total
electrical rating |
kW |
0.11 |
0.15 |
0.23 |
0.23 |
0.23 |
0.31 |
0.51 |
| Sound
pressure level (Lp)@5m |
free
field |
dB(A) |
44 |
44 |
47 |
47 |
47 |
48 |
51 |
typical
installation |
dB(A) |
51 |
51 |
54 |
54 |
54 |
55 |
58 |
Suggested
mounting
height (5) |
m |
2.0-2.5 |
2.0-2.5 |
2.5-3.0 |
2.5-3.0 |
2.5-3.0 |
2.5-3.5 |
2.5-3.5 |
| Approximate
weight |
kg |
72 |
84 |
100 |
100 |
116 |
145 |
183 |
|
| |
| |
1.
Throw depends on height of building, mounting height of heater, room
temperature and louvre settings |
| |
2.
Natural Gas minimum inlet pressure 17.5 mbar, maximum inlet
pressure 50mbar |
| |
3.
Propane Gas minimum inlet pressure 37 mbar, maximum inlet pressure
50mbar |
| |
4.
Not supply line size |
| |
5.To underside of heater |
|
| |
|
| |
 |
| |
|
| |
 |
| |
| MODEL |
unit |
UCA
25 |
UCA
30 |
UCA
35 |
UCA
45 |
UCA
55 |
UCA
75 |
UCA
95 |
| Cabinet
width |
A |
520 |
590 |
730 |
730 |
870 |
1080 |
1360 |
| Access
side to flue centre |
B |
290 |
325 |
395 |
395 |
465 |
570 |
710 |
| Side
clearance non control side |
C |
150 |
150 |
150 |
150 |
150 |
300 |
300 |
| Access
side clearance |
D |
550 |
620 |
750 |
750 |
900 |
1100 |
1400 |
| Cabinet
back to flue outlet |
E |
127 |
137 |
151 |
151 |
162 |
162 |
169 |
| Flue
outlet diameter (inches) |
F |
5 |
6 |
7 |
7 |
8 |
8 |
10 |
| Depth
axial fan |
G |
218 |
249 |
278 |
278 |
318 |
249 |
318 |
| Suspension
centres |
H |
359 |
429 |
569 |
569 |
709 |
919 |
1199 |
|
|
| |
| |
All
dimensions in mm except flue outlet diameter which is in inches. |
| |
|
|
| |
|